Download Files |
Engineers Sample Calm PTHP Mechanical Schedules 208 - 230: CLICK HERE |
Engineers Sample Calm PTHP Mechanical Schedules 277: CLICK HERE |
Calm 42 Specification : CLICK HERE |
Calm 42 PDF Brochure : CLICK HERE |
208/230v |
A42H Heatpump with Electric Heat |
|||
A42HC07K |
A42HC09K |
A42HC12K |
A42HC15K |
|
Cooling BTUH |
7545/7592 |
9012/9363 |
12420/9363 |
14876/16582 |
EER |
12.2/12 |
11.4/11.3 |
10.5/10.7 |
9.7/9.8 |
Cooling Amps |
3.0/2.8 |
3.9/3.7 |
5.3/5.1 |
7.5/6.7 |
Minimum Circuit Amps |
3 |
5.36 |
7.87 |
11.03 |
Cooling Watts |
620/640 |
770/800 |
1100/1120 |
1510/1530 |
Heating BTUH |
6067/6244 |
8383 |
10724/10983 |
13177/13314 |
C.O.P. |
3.4/3.4 |
3.3/3.3 |
3.1/3.1 |
2.9/2.9 |
HeatPump Ames |
2.4/2.5 |
3.6/3.4 |
4.7/4.5 |
6.6/6.0 |
HeatPump Watts |
530/540 |
700/720 |
990/1010 |
1370/1390 |
Dehumid. Pints/hr |
1 |
1.7 |
3.5 |
4.7 |
Airflow CFM |
294/277/260 |
294/277/260 |
312/294/277 |
341/324/306 |
Indoor Sound dB (A) |
49/48/47 |
51/50/49 |
53/52/51 |
53/52/51 |
Outdoor Sound dB (A) |
61/59/57 |
61/59/57 |
63/61/59 |
63/61/59 |
Net Wt/Ship Wt lb |
113/132 |
113/132 |
117/138 |
119/140 |
Power Cord Options |
||||
2.0kW-A42CORD-15AMP-230v |
Yes |
Yes |
Yes |
Yes |
3.0kW-A42CORD-20AMP-230v |
Yes |
Yes |
Yes |
Yes |
5.0kW-A42CORD-30AMP-230v |
No |
No |
Yes |
Yes |
277v |
A42H Heatpump with Electric Heat |
|||
A42HC07R |
A42HC09E |
A42HC12R |
A42HC15R |
|
Cooling BTUH |
7592 |
9000 |
12372 |
15136 |
EER |
12 |
11.3 |
10.7 |
9.8 |
Cooling Amps |
2.4 |
3.7 |
4.8 |
5.9 |
Minimum Circuit Amps |
3 |
3.91 |
5.52 |
7.31 |
Cooling Watts |
640 |
800 |
1120 |
1530 |
Heating BTUH |
6244 |
7776 |
11079 |
1390 |
C.O.P. |
3.3 |
3.3 |
3.1 |
2.9 |
HeatPump Ames |
2.1 |
3.4 |
4.5 |
5.25 |
HeatPump Watts |
540 |
720 |
1010 |
1390 |
Dehumid. Pints/hr |
1 |
1.7 |
3.5 |
4.7 |
Airflow CFM |
294/277/260 |
294/277/260 |
312/294/277 |
341/324/306 |
Indoor Sound dB (A) |
61/59/57 |
61/59/57 |
63/61/59 |
63/61/59 |
Outdoor Sound dB (A) |
113/133 |
61/59/57 |
63/61/59 |
63/61/59 |
Net Wt/Ship Wt lb |
113/133 |
113/133 |
117/138 |
119/140 |
Power Cord Options |
||||
2.0kW-A42CORD-15AMP-230v |
Yes |
Yes |
Yes |
Yes |
3.0kW-A42CORD-20AMP-230v |
Yes |
Yes |
Yes |
Yes |
5.0kW-A42CORD-30AMP-230v |
No |
No |
Yes |
Yes |
A42E- A42E Power Cord Selection Chart |
||||||
Power Cord Selections: CALM A42 Series PTAC's and PTHPs are not equipped with a power cord. A power cord MUST be ordered separaely based on the voltage and amperage of the electrical circut. Electric heating capacity will be determined by the power cord selected separately. 30 Amp cords should not be used with 7000 or 9000 BTU/Hr. units. |
||||||
208 / 230v |
||||||
Part Number of Power Cord |
Heater kw |
*MOP Amps |
Heating BTUH |
Total Watts |
Total Amps |
|
A42CORD-15A-230V |
2.0 |
15 |
5581/6824 |
1643/2047 |
8.9/7.9 |
|
A42CORD-20A-230V |
3.0 |
20 |
8372/10236 |
2496/3036 |
13.2/12.2 |
|
A42CORD-30A-230V |
5.0 |
30 |
13953/17060 |
4118/5037 |
21.5/20.5 |
|
277v |
EERA42CORD-15A-277V |
2.0 |
15 |
6800 |
2000 |
8.9 |
EERA42CORD-20A-277V |
3.0 |
20 |
10200 |
3000 |
13.2 |
|
EERA42CORD-30A-277V |
5.0 |
30 |
17000 |
5000 |
21.5 |
|
*Maximum Overcurrent Protection // Branch Circut Fuse Amps |